• Higher Temperature Capability
The polypropylene construction offers thermal resistance for cable routing in environments with elevated operating temperatures, providing a protective outer covering for wire harnesses.
• Reliable Mechanical Protection
The corrugated wall helps protect cables from external friction, scratches and everyday impacts, reducing the risk of mechanical damage during equipment operation.
• Chemical Exposure Resistance
Polypropylene offers resistance to acids, alkalis and certain chemical solvents, supporting cable protection in industrial environments where such exposure may occur.
• Lightweight Cable Management
The lightweight tubing organizes multiple wires into a single bundle while adding minimal weight to the cable assembly.
• Flexible Installation and Routing
The flexible corrugated profile accommodates practical bends and routing paths, supporting convenient cable insertion and installation.
• Polypropylene Construction
Manufactured from polypropylene (PP), offering a lightweight structure, chemical resistance and dimensional stability.
• Flexible Corrugated Profile
The corrugated profile provides flexibility for installation along different cable routing paths.
• Abrasion and Impact Resistance
The polypropylene corrugated wall helps absorb minor impacts and reduce contact abrasion on enclosed cables.
• Electrical Insulation Properties
Polypropylene has electrical insulation properties and provides additional external cable coverage, but does not replace the insulation of individual conductors.
• Resistance to Acids and Alkalis
The material resists certain acids, alkalis and chemical media, with compatibility depending on concentration, temperature and exposure duration.
| Material |
Polypropylene (PP) |
| Style |
Non-split |
| Working Temperature |
−40°C to +105°C |
| Melting Point |
170 ± 10°C |
| Heat Aging Resistance |
No embrittlement and chalking after test at 150℃ for 240h per QC/T29106 |
| Flammability |
UL94 V2 |
| RoHS Compliance |
Yes |
| Standard Color |
Black |
| Part No |
I.D (mm) |
O.D (mm) |
Wall Thickness (mm) |
Packing Length (m/spool) |
| WL-PP-N-4.5*7.0-BK |
4.5 ± 0.5 |
7.0 ± 0.5 |
0.25 ± 0.1 |
500 |
| WL-PP-N-5.5*7.5-BK |
5.5 ± 0.5 |
7.5 ± 0.5 |
0.25 ± 0.1 |
500 |
| WL-PP-N-6.5*9.2-BK |
6.5 ± 0.5 |
9.2 ± 0.5 |
0.25 ± 0.1 |
500 |
| WL-PP-N-7.5*10.5-BK |
7.5 ± 0.5 |
10.5 ± 0.5 |
0.25 ± 0.1 |
400 |
| WL-PP-N-8.5*11.5-BK |
8.5 ± 0.5 |
11.5 ± 0.5 |
0.25 ± 0.1 |
400 |
| WL-PP-N-10.0*13.0-BK |
10.0 ± 0.5 |
13.0 ± 0.5 |
0.25 ± 0.1 |
300 |
| WL-PP-N-12.0*15.8-BK |
12.0 ± 0.5 |
15.8 ± 0.5 |
0.30 ± 0.1 |
200 |
| WL-PP-N-13.0*17.4-BK |
13.0 ± 0.5 |
17.4 ± 0.5 |
0.30 ± 0.1 |
200 |
| WL-PP-N-14.5*18.5-BK |
14.5 ± 0.5 |
18.5 ± 0.5 |
0.30 ± 0.1 |
200 |
| WL-PP-N-16.0*20.0-BK |
16.0 ± 0.5 |
20.0 ± 0.5 |
0.30 ± 0.1 |
150 |
| WL-PP-N-17.0*21.2-BK |
17.0 ± 0.5 |
21.2 ± 0.5 |
0.30 ± 0.1 |
150 |
| WL-PP-N-19.0*23.5-BK |
19.0 ± 0.5 |
23.5 ± 0.5 |
0.30 ± 0.1 |
100 |
| WL-PP-N-20.5*25.0-BK |
20.5 ± 0.5 |
25.0 ± 0.5 |
0.35 ± 0.1 |
100 |
| WL-PP-N-21.0*25.8-BK |
21.0 ± 0.5 |
25.8 ± 0.5 |
0.35 ± 0.1 |
100 |
| WL-PP-N-23.0*28.0-BK |
23.0 ± 0.5 |
28.0 ± 0.5 |
0.35 ± 0.1 |
100 |
| WL-PP-N-25.0*31.5-BK |
25.0 ± 0.5 |
31.5 ± 0.5 |
0.35 ± 0.1 |
50 |
| WL-PP-N-29.0*34.5-BK |
29.0 ± 0.5 |
34.5 ± 0.5 |
0.40 ± 0.1 |
50 |
| WL-PP-N-32.0*38.0-BK |
32.0 ± 0.5 |
38.0 ± 0.5 |
0.40 ± 0.1 |
50 |
| WL-PP-N-36.0*42.5-BK |
36.0 ± 0.5 |
42.5 ± 0.5 |
0.40 ± 0.1 |
40 |
| WL-PP-N-42.0*48.0-BK |
42.0 ± 0.5 |
48.0 ± 0.5 |
0.45 ± 0.1 |
30 |
| WL-PP-N-48.0*54.5-BK |
48.0 ± 0.5 |
54.5 ± 0.5 |
0.45 ± 0.1 |
30 |
• Automotive Wiring Harnesses
Protects automotive wiring harnesses against vibration, friction and routine mechanical contact, including suitable engine-compartment routing locations.
• Industrial Machinery Wiring
Protects cables and connecting wires inside industrial machinery from abrasion caused by contact with brackets, housings and other components.
• Electrical Equipment
Organizes and protects internal wiring in electrical equipment, supporting neat cable routing and efficient assembly.
• Industrial Automation Systems
Provides additional mechanical protection for cable bundles in automated production equipment, control units and related assemblies.
• Automotive Electrical Assemblies
Supports cable organization in automotive electrical assemblies where flexibility, thermal resistance and mechanical protection are required.
Measure the total outside diameter of the cable bundle and select a WL-PP-N inside diameter that provides sufficient clearance for wire insertion without excessive looseness. Consider the largest connector or terminal that must pass through the tubing during assembly.Evaluate the operating temperature, routing space, bend radius, vibration, abrasion exposure and possible contact with chemicals. For installations involving acids, alkalis or solvents, confirm material compatibility under the actual concentration, temperature and exposure conditions.As WL-PP-N features a non-split construction, cables must be inserted from an open end. Confirm the installation sequence and tubing length before assembly. For demanding applications, verify the finished cable assembly under representative operating conditions.
• Sizes and Dimensions - Multiple standard inside diameters, outside diameters and wall thicknesses are available. Special dimensions can be reviewed according to project requirements.
• Colors and Identification - Black is the standard color. Alternative colors and product identification requirements can be reviewed according to material availability, production feasibility and order quantity.
• Packaging - Spool packaging, quantity-based packing, product labels and carton markings can be arranged according to order requirements.
• Polypropylene Material Verification - Polypropylene raw materials are checked against approved product specifications and manufacturing requirements.
• Corrugation Profile Control - Corrugation shape, pitch and structural uniformity are inspected to support consistent construction and installation performance.
• Dimensional Inspection - Inside diameter, outside diameter and wall thickness are verified against the specified tolerances for each part number.
• Flexibility and Appearance Inspection - Tubing flexibility and appearance are inspected for cracks, deformation, contamination and other visible defects.
• Final Inspection and Traceability - Part numbers, dimensions, color, quantities, packaging and labels are verified before shipment, with batch records maintained according to order requirements.
Frequently Asked Questions
1. What is WL-PP-N polypropylene non-split wire loom tubing used for?
WL-PP-N is used to organize and protect cable bundles in automotive wiring harnesses, electrical equipment and industrial machinery. Its corrugated construction helps reduce everyday abrasion and mechanical contact.
2. What is the difference between PP and PE wire loom tubing?
PP and PE wire loom tubing differ in material properties, including temperature capability, flexibility and chemical resistance. Selection should also consider routing and environmental requirements.
3. Can WL-PP-N be installed over existing cables with connectors?
WL-PP-N has a non-split construction, so cables normally need to be inserted from an open end. Connectors larger than the tubing inside diameter may need to be installed after the tubing is fitted.
4. Can polypropylene wire loom tubing resist chemical exposure?
Polypropylene offers resistance to certain acids, alkalis and chemical solvents. Actual compatibility depends on the specific chemical, concentration, temperature and exposure duration.
Request a Sample or Quote
Please share your cable bundle diameter, required tubing dimensions, operating temperature, routing conditions, required spool and estimated annual order quantity. If the application involves chemical exposure or repeated movement, include the relevant operating details.MJ FLEX can help evaluate suitable WL-PP-N sizes, wall thicknesses and packaging options, and provide samples or quotations based on your project requirements.